Descripción

Function Release delayed, fixed or adjustable time range
Cat. / PL according to EN ISO 13849-1 2/c
SIL CL according to IEC/EN 62061 2
1- / 2-channel 1
Output contacts max. 1 s, 1 o
Nominal voltage DC +
Nominal voltage AC +
Thermal current Ith max. 8 A
Time delay max. 10 s
Removable terminals +
Width 52,5 mm
Type IN 7824
According to- Performance Level (PL) c and category 2 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061- Safety Integrity Level (SIL) 2 to IEC/EN 61508- Category 2 to EN 954-1 BA 7924.21/002 und BA 7924.21/003- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 2 nach IEC/EN 62061- Safety Integrity Level (SIL) 2 to IEC/EN 61508- Category 3 to EN 954-1 Release delay Without auxiliary voltage Output: 1 NC, 1 NO contacts, forcibly guided Operating state display Optionally with adjustable or fixed time delay up to 30 s Optionally with redundant timing circuit Optionally with 1 or 2 separate timing circuits Optionally also in housing for distribution board Width 45 mm, 35 mm or 52.5 mm''