Descripción

Function Release delayed, fixed or adjustable time range
Cat. / PL according to EN ISO 13849-1 3/d
SIL CL according to IEC/EN 62061 2
1- / 2-channel 1, 2
Output contacts max. 4 s, 1 o
Nominal voltage DC +
Thermal current Ith max. 5 A
Time delay max. 300 s
Width 22,5 mm
Type LG 7928
According to- Performance Level (PL) d and category 3 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061- Safety Integrity Level (SIL) 2 to IEC/EN 61508 and IEC/EN 61511when connected to a suitable safety module Adjustable time delay As option fixed time delay High long life stability due to digital time base Adjustable with or without cross fault detection Output: 3 NO contacts + 1 NC contact + 1 forcibly guidedfeedback contactor 4 NO contacts + 1 1 forcibly guided feedback contact LED indicator for channel 1, 2 and operation voltage Wire connection: also 2 x 1.5 mm2 stranded ferruled, or2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4 As option with pluggable terminal blocks for easy exchangeof devices- with screw terminals- or with cage clamp terminals Width 22.5 mm''