Descripción

Function Switch gear for safety switch
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1, 2
Output contacts max. 4 s
Thermal current Ith max. 8 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC +
Removable terminals +
Width 22,5 mm
Type LG 5925/920
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 According to EN 50156-2 for furnaces to connect:- safety switch NE 5020- safety switch NE 5021 Output: max. 4 NO contacts, see contacts 1- or 2-channel operation Line fault detection on On-button Manual restart or automatic restart, switch S2 with or without cross fault monitoring switch S1 LED indicator for state of operation LED indicator for channel 1 and 2 Wire connection: also 2 x 1.5 mm2 stranded ferruled, or2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4 As option with plugable terminal blocks for easy exchangeof devices- with screw terminals- or with cage clamp terminals Width 22.5 mm''